ORP2XX
Epoxy body bulb electrode
Bulb ORP Electrodes with epoxy body
This FLS line of electrodes
has been designed to
provide a cost effective multipurpose
solution for in line or
submersion measurement of
pH and ORP in a wide range of
applications.
Single and double junction
versions are available as well
as models with or without quick
disconnect top caps. Moreover
for automatic temperature
compensation function (ATC)
a pH option with temperature
sensor integrated is available.
These epoxy body electrodes
can stand several applications
thanks to the high chemical
resistance of the material. A
simple and reusable gland
can be used for economic
electrode in-line mounting
while a ½” or ¾” coupler with
a pipe extension is enough
for submersion mounting. A
special version is dedicated to
installation on FLS T fitting as
well as to FLS clamp saddle
adding just a nut.
Reference | Name | Product description | product.detail.attribute.technicalFeatures | dimensionalTable | Main category | Subcategory | Sub sub category | system | Category | family | series | Features | Operative Range | Cable** | Connection | Installation | Weight (gr.) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ORP200C | ORP2XX | This FLS line of electrodes has been designed to provide a cost effective multipurpose solution for in line or submersion measurement of pH and ORP in a wide range of applications. Single and double junction versions are available as well as models with or without quick disconnect top caps. Moreover for automatic temperature compensation function (ATC) a pH option with temperature sensor integrated is available. These epoxy body electrodes can stand several applications thanks to the high chemical resistance of the material. A simple and reusable gland can be used for economic electrode in-line mounting while a ½” or ¾” coupler with a pipe extension is enough for submersion mounting. A special version is dedicated to installation on FLS T fitting as well as to FLS clamp saddle adding just a nut. | APPLICATIONS: Water treatment Neutralization systems Water quality monitoring Swimming Pools and spas Aquaculture Agriculture and fertilizing systems Process control MAIN FEATURES: Epoxy body Single or double junction technology Large gel reference volume Easy and quick installation system Outline cable or BNC connection Version with temperature sensor combined Special versions on request Low cost fittings | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 200 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | Singol junction | ± 2000 mV | Not required | 5m $ (16,5 ft.) Cable | EG50P $ EG75P $ MK150200 $ MIFV20X05 $ MIMC20X05 | 200 |
ORP222CD | ORP2XX | This FLS line of electrodes has been designed to provide a cost effective multipurpose solution for in line or submersion measurement of pH and ORP in a wide range of applications. Single and double junction versions are available as well as models with or without quick disconnect top caps. Moreover for automatic temperature compensation function (ATC) a pH option with temperature sensor integrated is available. These epoxy body electrodes can stand several applications thanks to the high chemical resistance of the material. A simple and reusable gland can be used for economic electrode in-line mounting while a ½” or ¾” coupler with a pipe extension is enough for submersion mounting. A special version is dedicated to installation on FLS T fitting as well as to FLS clamp saddle adding just a nut. | APPLICATIONS: Water treatment Neutralization systems Water quality monitoring Swimming Pools and spas Aquaculture Agriculture and fertilizing systems Process control MAIN FEATURES: Epoxy body Single or double junction technology Large gel reference volume Easy and quick installation system Outline cable or BNC connection Version with temperature sensor combined Special versions on request Low cost fittings | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 200 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | Double junction | ± 2000 mV | CN 653 | Twist-lock (BNC) | EG50P $ EG75P $ MIFV20X05 $ MIMC20X05 | 90 |
ORP223CD | ORP2XX | This FLS line of electrodes has been designed to provide a cost effective multipurpose solution for in line or submersion measurement of pH and ORP in a wide range of applications. Single and double junction versions are available as well as models with or without quick disconnect top caps. Moreover for automatic temperature compensation function (ATC) a pH option with temperature sensor integrated is available. These epoxy body electrodes can stand several applications thanks to the high chemical resistance of the material. A simple and reusable gland can be used for economic electrode in-line mounting while a ½” or ¾” coupler with a pipe extension is enough for submersion mounting. A special version is dedicated to installation on FLS T fitting as well as to FLS clamp saddle adding just a nut. | APPLICATIONS: Water treatment Neutralization systems Water quality monitoring Swimming Pools and spas Aquaculture Agriculture and fertilizing systems Process control MAIN FEATURES: Epoxy body Single or double junction technology Large gel reference volume Easy and quick installation system Outline cable or BNC connection Version with temperature sensor combined Special versions on request Low cost fittings | - | Automation system | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | pH/ORP 200 | Automation system | FLS Measurement and control Instrumentation | ph / ORP / Conductivity Electrodes | Bulb and Flat pH/ORP Electrodes with Epoxy, C-PVC, Ryton or Glass body | Double junction for FLS fittings | ± 2000 mV | CN 653 | Twist-lock (BNC) | F3.SP2.4 | 100 |
APPLICATIONS:
- Water treatment
- Neutralization systems
- Water quality monitoring
- Swimming Pools and spas
- Aquaculture
- Agriculture and fertilizing systems
- Process control
MAIN FEATURES:
- Epoxy body
- Single or double junction technology
- Large gel reference volume
- Easy and quick installation system
- Outline cable or BNC connection
- Version with temperature sensor combined
- Special versions on request
- Low cost fittings